    Basic Introduction
    DSCD-920 Transmitted liquid Tabletop Spectrophotometer is good performance and specially designed for testing the liquid transmittance, absorbance, concentration, chrominance and other parameters. The instrument adopts the measurement structure of D/0, integration of the full band LED composite light source, double beam optical system, ETC every-time calibration technology, which makes the instrument reaches a resolution of 0.0001, deviation of the transmittance within 0.08% and chromatic value: △E*ab 0.015.


    Brief Introduction
    • Transmission D/0 Structure and Reflection D/8 Structure

    • Double Optical Paths Spectral Analysis Technology
    It could get the measurement sample data and internal environment data at the same time to make sure the testing accuracy and stability for long time running.

    • Compatible with SCI/SCE Measurement
    Adopt D/8 illuminant condition recommended by the CIE to meet the color testing requirement for different industries. It could measure with SCI and SCE to see the color data change more clearly.
    • Four Testing Calibers
    It is easy to adjust the testing calibers. The largest caliber diameter reaches 25.4mm. It could test the sample with different sizes.
    • Large screen display and Stand-alone operation
    • Unique Calibration Board Design
    • Flexible Test Fixture

    Technical Data

    TypeDSCD-920
    Measurement ConditionReflection: d/8 (Diffused lighting, 8 degrees receiving) Compatible with SCI/SCE Measurement ISO7724/1、DIN5033 Teil7、JIS Z8722 condition C、CIE No.15、ASTM E1164 Transmission d/0 (Diffused lighting, Vertical direction receiving)
    Size of integrating sphereΦ15.2cm, Alvan diffused reflection surface coating
    Illumination Light sourceCLEDs (entire wavelength balanced LED light source)
    Sensordual light path sensor array
    Wavelength range400-700nm
    Wavelength interval10nm
    Half spectral width5nm
    Reflectivity range0-200%
    Reflectivity resolution0.01%
    Observation angle2°/10°
    Measurement light sourceA, C, D50, D55, D65, D75, F1, F2, F3, F4, F5, F6, F7, F8, F9, F10, F11, F12, CWF, U30, DLF, NBF, TL83, TL84
    Data being displayedSPD distribution/data, sample’s color values, color difference values/graph, pass/fail results, color error tendency, history data color simulation, manual input standard sample, generate measurement report
    Measurement time interval2 seconds

    Reflection Aperture



    Large Aperture (LAV): 2.54cm (=1inch)
    Medium Aperture (MAV): 1.5cm (=0.6inch)
    Small Aperture (SAV): 0.75cm x 1.0cm (0.3inch x 0.4inch)
    Very Small Aperture (VSAV): 0.3cm x 0.8cm (0.12inch x 0.31inch)
    Color spaceCIE-L*a*b, L*C*h, CIE-L*u*v, XYZ, Yxy, Transmittance, Hunterlab, Munsell MI, CMYK, RGB, HSB
    Color difference formulasΔE*ab, ΔE*CH, ΔE*uv, ΔE*cmc (2:1),  ΔE*cmc (1:1), ΔE*94, ΔE*00, ΔEab (Hunter), 555color classification
    Other colorimetric indicesWI (ASTM E313-10, ASTM E313-73, CIE/ISO, AATCC, Hunter, Taube Berger, Ganz, Stensby), YI (ASTM D1925, ASTM E313-00, ASTM E313-73), Tint (ASTME313-00, CIE, Ganz), Metamerism index Milm, Stick color fastness, Color fastness, APHA, Pt-Co, Gardner
    Repeatabilitylight splitting reflectivity: standard deviation within 0.08%
    color values: ΔE*ab <=0.015 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals, Maximum: 0.03)
    InterfaceUSB
    Data storagemass storage
    Light source longevity5 years, 1.5 million tests
    Size583*330*304mm (L*W*H)
    Work temperature range15℃-32℃ (60°F-90°F)
    Relative Humidity0℃ to 45℃, relative humidity 80% or below (at 35°C), no condensation
    Standard accessoriesAC power line, color management software, drive software, USB cable, black/white calibration tube, 40*10 cuvette, cuvette support, testing report
    Optional40×40 cuvette